CivilBay                          
                             
 Home  > Concrete  > Concrete Anchorage  > Anchor Bolt / Anchor Stud Design Using ACI 318M-11 / ACI 318M-14 - Quick Input
                                       
Skip Navigation Links                     ToolTip :  Login

                   
ANCHOR BOLT DESIGN ACI 318M-14 Code - Using Anchor Reinforcement    

Result Summary                  
Anchor Rod Embedment, Spacing and Edge Distance       OK  
Min Rquired Anchor Reinft. Development Length ratio = 0.87 OK  
Overall         ratio = 1.21 NG  
Seismic Design         Tension =   OK  
          Shear =   OK  

                Code Reference
Select anchor bolt design code          
Select design using or not using anchor reinforcement      
Select design for anchor bolt or anchor stud          
Concrete strength f'c = [MPa]    
Anchor Bolt Data                    
Anchor bolt material   =          
Anchor tensile strength futa = 400 [MPa]         ACI 318M-14
      Anchor is ductile steel element       2.3 & 17.3.3 (a)
Anchor bolt diameter da  = [in]            
Anchor bolt has sleeve   =           PIP STE05121
Anchor bolt head type            
Anchor effective cross section area Ase = 391 [mm2]        
Anchor bolt head bearing area Abrg = [mm2]
Anchor bolt 1/8" (3mm) corrosion allowance =            
Select anchor bolt pattern        
 
c1=127 s1=406 c3=127 c2=127 s2=406 c4=127 Nu=-44.5 Mux=33.9 Vuy=111.2 Muy=20.3 Vux=66.7
c1=127 s1=406 c3=127 c2=127 s2=406 c4=127 col dx=323 col dy=323
                   
Anchor Bolt Forces                    
Factored tension or compression Nu = [kN] in compression    
  Anchor Bolt Forces in Y Axis Direction             Anchor Bolt Forces in X Axis Direction    
Factored moment Mux = [kN-m] Muy = [kN-m]    
Mux and Muy are concurrent =              
Factored shear force Vuy = [kN] Vux = [kN]    
Anchor Bolt Group Layout Dimensions            
  Anchor Bolt Exterior Bolt Line Spacing             PIP STE05121
Exterior bolt line spacing s1 s1 = [mm] 102   OK   Page A -1 Table 1
Exterior bolt line spacing s2 s2 = [mm] 102   OK    
  Anchor Bolt Edge Distance         PIP STE05121
Anchor bolt edge distance c1 c1 = [mm] 114   OK   Page A -1 Table 1
Anchor bolt edge distance c2 c2 = [mm] 114   OK    
Anchor bolt edge distance c3 c3 = [mm] 114   OK    
Anchor bolt edge distance c4 c4 = [mm] 114   OK    
  Column Depth                
Column depth in X axis direction dx = [mm]            
Column depth in Y axis direction dy = [mm]            
                  PIP STE05121
Anchor bolt embedment depth hef = [mm] 305   OK   Page A -1 Table 1
Pedestal height ha = [mm] 431   OK    
Anchor Reinforcement Input         ACI 318M-14
To be considered effective for resisting anchor tension, vertical reinforcing bars shall be located R17.4.2.9
within 0.5hef from the outmost anchor's centerline  
Avg ver. bar center to anchor rod center distance dar = [mm]  
No of ver. rebar effective to resist tensile anchors - Mux case n-Mux =    
No of ver. rebar effective to resist tensile anchors - Muy case n-Muy =    
Rebar specification   =        
Ver. rebar size No. = 25.4 [mm] single rebar area As = 509 [mm2]  
Ver. rebar top anchorage option        
To be considered effective for resisting anchor shear, hor. reinft shall be located R17.5.2.9
within min( 0.5c1, 0.3c2 ) from the outmost anchor's centerline min (0.5c1, 0.3c2) = 38 [mm]  
No of tie layer that are effective to resist anchor shear nlay =    
No of tie leg that are effective to resist anchor shear Vux nleg-Vux =    
No of tie leg that are effective to resist anchor shear Vuy nleg-Vuy =    
Hor. tie rebar size No. = 12.7 [mm] single rebar area As = 129 [mm2]  
For anchor reinft shear breakout strength calc    
Rebar yield strength - ver. rebar fy-v = [MPa]        
Rebar yield strength - hor. rebar fy-h = [MPa]        
Consider only half of total anchor bolt carrying shear due to oversize bolt hole =            
Provide built-up grout pad ?   =           17.5.1.3
Seismic Input             ACI 318M-14
Seismic design category SDC >= C   =           17.2.3.1
Anchor bolt load E <= 0.2U Tensile =   Shear =   17.2.3.4.1 & 17.2.3.5.1
Anchor bolt satisfies opion Tensile = Shear = 17.2.3.4.3 & 17.2.3.5.3

CONCLUSION
                 

  Result for Anchor Bolt Forces in Y Axis Direction         View Detail Calc
Anchor Rod Embedment, Spacing and Edge Distance       OK ACI 318M-14
Min Rquired Anchor Reinft. Development Length ratio = 0.87 OK 25.4.3.1
Overall ratio = 1.21 NG  
Tension          
Anchor Rod Tensile Resistance ratio = 0.31 OK  
Anchor Reinft Tensile Breakout Resistance ratio = 0.15 OK  
Anchor Pullout Resistance ratio = 0.25 OK  
Side Blowout Resistance ratio = 0.28 OK  
Shear          
Anchor Rod Shear Resistance ratio = 1.14 NG  
Anchor Reinft Shear Breakout Resistance          
      Strut Bearing Strength ratio = 0.45 OK  
      Tie Reinforcement ratio = 0.69 OK  
Conc. Pryout Not Govern When hef >= 12da       OK  
Tension Shear Interaction          
Tension Shear Interaction ratio = 1.21 NG  
           
Seismic Design         ACI 318M-14
Tension Applicable       OK 17.2.3.4
Seismic SDC>=C and E>0.2U , Option D is selected to satisfy additional seismic requirements as per D.3.3.4.3    
                   
Shear Applicable       OK 17.2.3.5
Seismic SDC>=C and E>0.2U , Option C is selected to satisfy additional seismic requirements as per D.3.3.5.3    

  Result for Anchor Bolt Forces in X Axis Direction         View Detail Calc
Anchor Rod Embedment, Spacing and Edge Distance       OK ACI 318M-14
Min Rquired Anchor Reinft. Development Length ratio = 0.87 OK 25.4.3.1
Overall ratio = 0.68 OK  
Tension          
Anchor Rod Tensile Resistance ratio = 0.15 OK  
Anchor Reinft Tensile Breakout Resistance ratio = 0.07 OK  
Anchor Pullout Resistance ratio = 0.12 OK  
Side Blowout Resistance ratio = 0.14 OK  
Shear          
Anchor Rod Shear Resistance ratio = 0.68 OK  
Anchor Reinft Shear Breakout Resistance          
      Strut Bearing Strength ratio = 0.27 OK  
      Tie Reinforcement ratio = 0.42 OK  
Conc. Pryout Not Govern When hef >= 12da       OK  
Tension Shear Interaction          
Tension Shear Interaction ratio = 0.00 OK  
           
Seismic Design         ACI 318M-14
Tension Applicable       OK 17.2.3.4
Seismic SDC>=C and E>0.2U , Option D is selected to satisfy additional seismic requirements as per D.3.3.4.3    
                   
Shear Applicable       OK 17.2.3.5
Seismic SDC>=C and E>0.2U , Option C is selected to satisfy additional seismic requirements as per D.3.3.5.3    

ToolTip