Verify AISC DG4 Bolt No Prying Assumption
AISC DG16 Is Used
Bolt Moment Strength (No Prying)
bolt grade
= A325-N
Ft
= 90.0
[ksi]
AISC 14th Table J3.2
bolt dia db
= 0.750
[in]
bolt area Ab
= 0.442
[in2]
Bolt norminal tensile strength
Pt
= Ft Ab
= 39.76
[kips]
AISC 14th Eq J3-1
Tension bolt moment arm
h0
= 13.705
[in]
h1
= 10.015
[in]
Bolt moment strength (no prying)
Mnp
= 2 Pt ( h0 + h1 )
= 157.19
[kip-ft]
AISC DG4 Eq 3.7
Bolt resistance factor-LRFD
φ
= 0.75
AISC 14th Eq J3-1
φ Mnp
=
= 117.89
[kip-ft]
End Plate Bending Strength
End plate width
bplate
= 8.490
[in]
thickness tp
= 0.750
[in]
Beam flange width
bfb
= 6.520
[in]
Effective end plate width
bp
= min ( bplate , bfb + 1" )
= 7.520
[in]
AISC DG4 Page 9 item 5
End plate yield strength
Fyp
= 50.0
[ksi]
See AISC DG4 Table 3.1 for all formulas to derive the following parameters
AISC DG4 Table 3.1
Tension bolt moment arm
h0
= 13.705
[in]
h1
= 10.015
[in]
g
= 4.000
[in]
pfi
= 1.625
[in]
pfo
= 1.625
[in]
s
= 2.742
[in]
Yp
= 88.61
[in]
Flexure resistance factor-LRFD
φb
= 0.90
AISC 14th F1 (1)
End plate bending strength
φb Mpl
= φb Fyp t2p Yp
= 186.90
[kip-ft]
AISC DG4 Table 3.1
Check thick end plate condition
φb Mpl >= 1.11 X φ Mnp
AISC DG4 Eq 3.33
ratio
= 0.70 thick plate
Column Flange Bending Strength
See AISC DG4 Table 3.4 for all formulas to derive the following parameters
AISC DG4 Table 3.4
Tension bolt moment arm
h0
= 13.705
[in]
h1
= 10.015
[in]
*** Unstiffened Column Flange Case ***
Column section
bfc
= 8.010
[in]
tfc
= 0.515
[in]
Fyc
= 50.0
[ksi]
bolt gage g
= 4.000
[in]
s
= 2.830
[in]
c
= 3.690
[in]
pfi
= 1.625
[in]
pfo
= 1.625
[in]
Yc
= 92.7
[in]
Flexure resistance factor-LRFD
φb
= 0.90
AISC 14th F1 (1)
Column flange bending strength
φb Mcf
= φb Fyc t2fc Yc
= 92.21
[kip-ft]
AISC DG4 Table 3.4
Check thick column flange condition
φb Mcf >= 1.11 X φ Mnp
AISC DG4 Eq 3.35
ratio
= 1.42 thin plate
The thick end plate and column flange conditions are NOT met. AISG DG16 is used and
bolt prying is considered
AISC DG4 Eq 3.33 & 3.35