Crane Runway Beam Span L2
L
2 --
crane runway beam span or building column bay spacing
It's common
that a building has different column bay spacings.
In
Crane-1
data input, user already input the
max.
column bay spacing of the
building as L
1.
In
Crane-2 data input, user can input the L
1 bay's neighbor
column bay spacing
as L
2 here as shown below.
The
input of L
2 will NOT affect crane runway beam design as long as
the L
1 input
is the max. column bay spacing of the whole
buiilding.
The input of L
2 may affect the crane beam
supporting column's vertical point
load and point moment caused by the
crane moving load.
The different combinations of L
1 and L
2
input may impact the crane beam
supporting column's vertical point load
and point moment caused by the crane
moving load.
When there are
different column bay spacings in a building, user may try different
L
1
and L
2 combinations, say L
1=30' L
2=20' and
L
1=20' L
2=30' to get different
sets of crane beam
supporting column's vertical point load and point moment and
use the max.
one for design.